Overview

Most of surgical procedures in head and neck region are dangerous because of cranial and peripheral nerve damage possibility. Mechanical trauma and ischemia are responsible for damage of nerves. Pain, functional disorders even cosmetic alteration of face can be observed after surgery. Intraoperative nerve monitoring presents information about position and functional status of the nerve in operating field and allow to minimize nerve damage during surgery. We present retrospective analysis and our findings in group of patients underwent surgery in head and neck region. Surgery was conducted under intraoperative monitoring of cranial nerves. Group of 122 patient underwent surgery in region of cerebellopontine angle (CPA) via translabyrinthine approach, 22 patients underwent surgery via retrosigmoid approach, 20 patients underwent surgery because of congenital malformations of external or middle ear, 5 patients underwent surgery via Fisch infratemporal approach A with transposition of facial nerve because of glomus tumor. 144 patients underwent surgery because of parotid gland tumor and 12 patients underwent surgery because of malignant thyroid gland tumor or revision surgery in this region. Relation of CPA tumor with amount till 2 cm to Berges formula average was confirmed as most significant (p< 0,001). Relation of early postoperative n.VII function with stimulation threshold 0,05 mA to early postoperative n. VII function with threshold over 0,1 mA was confirmed as significant (p< 0,001) and also relation of late postoperative n.VII function with stimulation threshold 0,05 mA to late postoperative n. VII function with threshold over 0,1 mA was confirmed as significant (p< 0,001).

Key words:
intraoperative cranial nerve monitoring.


Sources

1. Berges, C., Fraysse, B., Yardeni, E., Rugiu, G.: Intraoperative facial nerve monitoring in posterior fossa surgery: prognostic value. Skull Base Surgery, 3, 1993, s. 214-216.

2. Bhattacharyya, N., Richardson, M. E., Gugino, L. D.: An objective assessment of the advantages of retrograde parotidectomy. Otolaryngol. Head Neck Surg., 131, 2004, 4, s. 392-396.

3. Brennan, J., Moore, E. S., Shuler, K. J.: Prospective analysis of the efficacy of continuous intraoperative nerve monitoring during thyroidectomy, parathyroidectomy and parotidectomy. Otolaryngol. Head Neck Surg,. 124, 2001, 5, s. 537-543.

4. Dulguerov, P., Marchal, F., Lehmann, W.: Postparotidectomy facial nerve paralysis: possible etiologic factors and results with routine facial nerve monitoring. Laryngoskope, 109, 1999, s. 754-761.

5. Grayeli, A. B., Guindi, S., Kalamarides, M., El Garem, H., Smail, M., Rey, A., Sterkers, O.: Four-chanel electromyography of the facial nerve in vestibular schwannoma surgery: sensitivity and prognostic value for short-term facial function outcome. Otol. Neurotik., 26, 2005, 1, s. 114-120.

6. Hermann, M., Hellebart, C., Freissmuth, M.: Neuromonitoring in thyroid surgery: prospective evaluation of intraoperative electrophysiological responses for the prediction of recurrent laryngea nerve injury. Ann. Surg., 240, 2004, 1, s. 9-17.

7. Kirkpatrick, P. J., Walters, M. B., Strong, A. J., Walliker, J. R., Gleeson, M. J.: Prediction of facial nerve function after surgery for cerebellopontine angle tumors. Use of facial nerve stimulator and monitor. Skull Base Surg., 1, 1991, s. 171-176.

8. Kovaľ, J., Šulla, I., Krempaská, S., Kaliarik, L., Almaši, M.: Hľadisko chirurga na zachovanie funkcie nervus facialis pri odstraňovaní vestibulárneho schwanómu translabyrintným prístupom. Otorinolaryng. a Foniat. /Prague/, 55, 2007, 4, s. 199-206.

9. Mikuni, N., Satow, T., Taki, J., Nishida, N., Enatsu R., Hashimoto, N.: Endotracheal tube electrodes to map and monitor activities of the vagus nerve intraoperatively. Technical Note. J. Neurosurg., 101, 2004, 3, s. 536-540.

10. Nissen, A. J., Sikand, A., Curto, F. S., Welsh, J. E., Gardi, J.: Value of intraoperative treshold stimulus in predicting postoperative facial nerve function after acoustic tumor resection. Am. J. Otol., 18, 1997, 2, s. 249-251.

11. O’Brien, C. J., Malka, V. B., Mijailovic, M. : Evaluation of 242 consecutive parotidectomies performed for benign and malignant disease. Austr. N. Z. Surg., 1993, 63, s. 870-877.

12. Prasad, S., Barry, E. H., Kamerer, D. B., Durrant, J., Sekhar, L. N.:Facial nerve function following cerebellopontine angle surgery: prognostic value of intraoperative tresholds. Am. J. Otol., 14, 1993 , 4, s. 330-333.

13. Robertson, M. L., Steward D. L., Gluckman J. L., Welge, J.: Continuous laryngeal nerve integrity monitoring during thyroidectomy: does it reduce risk of injury? Otolaryngol. Head Neck Surg., 131, 2004, 5, s. 596-600.

14. Samii, M., Matthies, C.: Management of 1000 vestibular schwannomas: the facial nerve – preservation and restitution of function. Neurosurgery, 40, 1997, 4, s. 696-706.

15. Schlake, H. P.Goldbrunner, R., Milewski, Ch., Krauss, J., Trautner, H., Behr, R., Sorensen, N., Helms, J., Roosen, K.: Intra-operative electromyographic monitoring of lower cranial motor nerves (LCM IX-XII) in skull base surgery. Clin. Neurol. Neurosurg., 103, 2001, 2, s. 72-82.

16. Selesnik, S. H., Cerew, J. F., Victor, J. D., Heise, C. W, Levine, J.:Predictive value of facial nerve electrofysiologic stimulation Tresholds in cerebellopontine – angle surgery. Laryngoscope, 106, 1996, 5 Pt1, s. 633‑638.

17. Selesnick, S. H.: Optimal stimulus duration for Intraoperative facial nerve monitoring. Laryngoskope, 109, 1999, s. 1376-1385.

18. Silverstein, H., Willcox, T. O., Rosenberg, S. I., Seidman, M. D.: Prediction of facial nerve function following acoustic neuroma resection using intraoperative facial nerve stimulation. Laryngoscope, 104, 1994, s. 539-544.

19. Taha, J. M., Tew, J. M., Keith, R. W.: Proximal – to – distal facial amplitude ratios as predictors of facial nerve function after acoustic neuroma excision. J. Neurosurg., 83, 1995, s. 994-998.

20. Watanabe, Y., Ischikawa, M., Shojaku, H., Mizokoshi, K.: Facial nerve palsy as a complication of parotid gland surgery and its prevention. Acta Otolaryngol., 1993, 504, s. 137-139.

21. Witt, R. L.: Facial nerve monitorng in parotid surgery: the standard of care? Otolaryngology Head and Neck Surgery, 119, 1998, 5, s. 468-470.

22. Yarbrough, D. E., Thompson G. B., Kasperbauer, J. L., Harper C. M., Grant, C. S.: Intraoperative electromyographic monitoring of the recurrent laryngeal nerve in reoperative thyroid and parathyroid surgery. Surgery, 136, 2004, 6, s. 1107-1115.

Labels
Audiology Paediatric ENT ENT (Otorhinolaryngology)
Login
Forgotten password

Enter the email address that you registered with. We will send you instructions on how to set a new password.

Login

Don‘t have an account?  Create new account

#ADS_BOTTOM_SCRIPTS#